Chapter 3 · 5 / 76 min readPDF page 88

Worked examples

Often the most challenging part of any computational design is getting a working, error-free, input file. Once we have that example input, we can modify it to determine many design elements and gain a better understanding of those parameters and their effects on our problem. In Example 3.1, we completed a simple single unit cell calculation for criticality for a UO2_2 fueled PWR. For this problem, we used most of the default parameters and the given geometry and materials for the initial calculation. Now we can adjust those elements and learn a great deal about our design and effects of changes to optimize both our calculations, materials and geometry. As a rule of thumb, only modify ONE parameter at a time when analyzing effects. If you change a material and its temperature and its density and the order of quadrature for the calculation, you will not have any idea which change affected the outcome. You could have changed two parameters that cancelled each other out and you will be unaware of the effect. Also, it is important to analyze the output and effect and make sure that the given change and response makes sense. If you change the amount of fissile material, you should see a change in the criticality in the calculation. Never take the output from a computer code at face value. If a calculation gives you an unexpected response, you need to verify that the calculation is correct and determine the underlying reason for the result.

The first variation we will perform in Example 3.2 is to change the order of quadrature , or SN_N, for our unit cell calculation. We will plot the changes in both criticality and computer time to see how the order of quadrature affects each.

Example 3.2

Given the PWR unit cell in Example 3.1, re-run the calculations in t-NEWT and change the order of quadrature from 2, to 4, 6, 8, 10, 12, 14, 16. Record the k∞_\infty and computer time for each calculation. Plot the results for each and analyze the effect of the order of quadrature on the reported value for criticality and the time for the calculation.

Solution: To change the order of quadrature, the only thing that must be adjusted is the line:

SCALE input — Example 3.2, listing 1
read parameters
sn=6
end parameters

Change 6 to 2 and run the model and record the results. NOTE: the official computer time is found at the end of the output file and not in the message block from Fulcrum. Continue for each until reaching SN_N = 16. Input results in a table for plotting.

Quadrature Orderk-infComputer Time (s)
21.3991607.28249
41.4023658.50198
61.40536511.4146
81.40542813.4041
101.40579017.2534
121.40573622.2252
141.40584526.6050
161.40580933.1177

The computer time may vary depending on the computer and processor speed. Any change in speed due to the machine’s capability should be proportional and the overall trend should look the same when plotted. The plot of criticality as a function of quadrature order looks like:

Example 3.2, listing 2

The plot of computer time as a function of quadrature order looks like:

Example 3.2, listing 3

When we look at the results, we see that computer time increases nearly exponentially as the order of quadrature increases. The criticality reported for the SN = 6 through SN_N = 16 are all very close (within 0.01% of each other)

For our simple unit cell single calculation, the overall time is still short (< 1 min). However, the time for an order 16 calculation is about 3 times as long as an order 6 calculation and the criticality results are the same out to 4 significant figures and are within 0.01% of each other. If we were doing many criticality calculations for a long depletion model, the time increase would be significant. The goal should be to get accurate results as efficiently as possible. Additional changes to our model that may speed up the calculation could be to collapse the cross sections energy groups from 252 to a more course structure such as 56 or 4 group models or making a broader mesh within the unit cell. We will not analyze those effects to the model at this time and will leave that to the problems at the end of this chapter. A more efficient method of running multiple calculations, versus changing a parameter and rerunning the code manually is to set up a restart within the input file. Information on doing a restart can be found in the SCALE manual.

By changing a parameter in the input, we can determine more about our model than just optimization of the calculation. For example, we can adjust the temperature of the fuel to determine the fuel temperature coefficient for the infinite reactor model. As presented in Example 1.3, the resonance cross section changes for many isotopes with temperature. Specifically, the resonances in the fuel will get wider at higher temperatures due to what is known as Doppler broadening. Within the life-cycle for neutrons in a thermal reactor, the increased width of the resonances increases the probability of resonance absorption as the neutrons scatter from high energies to low energies. The effect is a reduction in the resonance escape probability (p) in the four-factor formula. The reduction in p causes a reduction in k. The overall effect is a negative feedback response where, as the temperature of the fuel increases, the criticality decreases and vice versa. The temperature coefficient, α\alpha, presented in Equation 3.5 is a measure of how much the criticality changes with temperature and has units of criticality per degree kelvin.

Equation 3.5
α=ΔkΔT\alpha = \frac{\Delta k}{\Delta T}

A negative coefficient is a safety design in a reactor. The temperature of the reactor is proportional to the flux and the power. As the power increases, the temperature and flux will increase. Because of the negative temperature coefficient, the increase in power and temperature will slow the response in criticality. This self-regulating feature makes reactors with a negative coefficient inherently stable and is a requirement for the licensing of reactors in the United States. In Example 3.3, we calculate the temperature coefficient for our infinite reactor model using our unit cell model.

Example 3.3

Given the PWR unit cell in Example 3.1, re-run the calculations in t-NEWT to calculate the fuel temperature coefficient for the infinite reactor model. Use an SN_N=6 quadrature and adjust the fuel temperature from room temperature (293 K) to 2093 k in increments of 200 k. Plot the results and use the slope of the line to determine the coefficient. Is it positive or negative? Do the results make sense?

Solution: To adjust the temperature of the fuel, change the value in the composition for the UO2_2 (shown below) from 1023 k to 293 k.

SCALE input — Example 3.3, listing 1
read comp
wtptuo2 1 10.2 2 92000 88.15 8000 11.85 1.0 1023
                92234 0.5 92235 4.5 92238 95.0 end
zirconium 2 den=6.407000 1.0 573.0 end
helium 3 1.0 573.0 end
water 4 den=0.715000 1.0 573.0 end
end comp

Run the model at each of the temperatures and record the results.

Fuel Temp (K)k-inf
2931.434917
4931.424811
6931.416695
8931.409628
10931.403209
12931.397407
14931.392006
16931.386895
18931.382012
20931.377342

Now plot the results and apply a linear trendline:

Example 3.3, listing 2

For our model, we can estimate the fuel temperature coefficient as:

α=−3.107382×10−5  Δkdegree  K\alpha = -3.107382 \times 10^{-5} \;\mathrm{\frac{\Delta k}{degree \;K}}

It is a negative coefficient which makes sense because of the Doppler broadening of the resonances at higher temperatures in the fuel which will decrease the resonance escape probability resulting in a lower k∞_\infty.

Computational Design in Nuclear Engineering, second edition, by Kenneth S. Allen, Ph.D., P.E. — the complete book as a 394-page PDF.

Download the PDF