By now we have used Attila4MC for a variety of fixed-source shielding applications. We have used both neutron and photon sources and we have explored the use of the CADIS variance-reduction methods. Attila is especially useful in setting up and running unstructured mesh problems on complex geometries. However, as of now, Attila will not run KCODE calculations to determine criticality. This is a limitation when the user desires to accurately calculate the dose rate from a criticality source such as a reactor or spent fuel pool.
It is possible to obtain an accurate model of the shielding from a criticality source using Attila if we break the problem into steps. First, the critical source must be modeled in MCNP. For a reactor, this would be the reactor core region. The user models the core region to include the water reflector just inside the pressure vessel. The model will have a vacuum boundary condition and the user will apply a F1 tally on the outside surface. The F1 tally will measure the current, or leakage on the outside surface of the model. The F1 tally will need to include several energy bins across the entire spectrum of energy from the source down to low-energy thermal neutrons. The results of the tally on the surface will be used to create a neutron source spectrum for the Attila model.
Once the results are known for the leakage from the criticality source, the user will be able to create a Parasolid matching the model with the addition of a thin region on the same surface where the F1 tally was taken in MCNP. This thin region will serve as a source region for the Attila run. If there is a significant difference in the spectrum from different sides of the model, multiple F1 tallies should be applied with multiple source definitions and regions. For most problems, the user can apply a single F1 tally on the outside of the criticality source and use a single region around the model.
As with any MCNP tally, the results are presented normalized to source particle. For a fixed source, we have calculated the tally multiplier several times to generate flux or dose rate per unit time. Calculating the tally multiplier for a critical source is performed by using the power of the model. Criticality problems always involve power. Power is normally measured in Watts or J/s. The recoverable energy per fission for thermal fission is approximately 200 MeV or Joules. Each fission from U gives off approximately 2.5 neutrons. For a critical source of Watts of power, the number of neutrons per second is computed using Equation 9.1 which reduces to Equation 9.2
Example 9.10 uses the same water-moderated subcritical assembly presented in Example 9.9 to create a neutron source from the F1 tally results from MCNP and then integrate the source spectrum into an Attila fixed-source calculation of dose rate with the appropriate tally multiplier for the system.
Example 9.10
A subcrital assembly consists of fuel rods of natural uranium in a light-water moderator and is pictured below.

The assembly details are given in the table below:
Specifications for USMA Subcritical Assembly
| Parameter | Value | |
|---|---|---|
| Tank | Diameter | 116.8 cm |
| Height | 152.4 cm | |
| Thickness | 0.59 cm | |
| Active Fuel Height | 145 cm | |
| Composition | Total: 276 rods | |
| Fuel: 271 | ||
| Neutron Source: 5 | ||
| Neutron Source | 1 Ci, Pu-Be | |
| Fuel Material | Natural Uranium | |
| Moderator | Light Water | |
| Fuel Holder (Lucite) | 0.287 cm | |
| Air Gap Thickness | 0.056 cm | |
| Fuel Thickness | 0.901 cm | |
| Second Air Gap Thickness | 0.017 cm | |
| Aluminum Clad Thickness | 0.121 cm | |
| Pitch (center-to center) | 5.0 cm |
For the given subcrital assembly, assume a power of Watts. Use Attila to calculate the dose rate to a person standing 1 meter from the side of the tank in mrem per hour and create a dose rate contour plot of the assembly in the room with a person standing 1 meter away.
Solution: To begin the process of using a criticality source in Attila, create an MCNP model of the subcritical assembly. The assembly is a hexagonal array in a triangular pitch. Modeling the individual unit cells and the assembly follows the same methods presented in Example 8.2 and 8.3 for the SCFR assembly. Add an F1:N tally to the outside surface of the subcrit. Include a wide and detailed distribution of energy bins to get a good spectrum for the neutrons exiting the tank. The results of the F1 tally will be the basis for the neutron source file for the Attila model. Determine the appropriate surface to apply the F1 tally. The easiest way to do so is to plot the model in Visual Editor or the MCNP Plotter and turn on the surface indices.

Recall that the F1 tally requires a surface number. The macrobody RCC for the tank outside has three surface (9.1, 9.2 and 9.3). For this model, the leakage as potential dose to our persons is best defined by the side surface (9.1). After the KCODE run is complete, export the tally results to Excel. We can plot the tally vs. energy as we did with the californium source creation in Example 9.4. Note there are several energy bins with zero hits. Apply a filter to hide the values that are zero before creating the Attila source or they will cause issues during the calculation.

The next step will require modeling the problem in Solidworks to create the solid body for use in Attila. For the Solidworks model, include everything in the subcrit and add a shell of air on the outside of the tank. This thin shell of air on the outside will serve as the source region in Attila. By explicitly modeling the interior geometry, the model accounts for the shielding provided by the core itself. Because of the complexity of the model, create the water region and the air inside within Solidworks and load the model as an MCNP vs. loading as an Attila method that will identify empty regions.

After the solid body and the source neutron distribution is created, the steps to modeling the problem are the same as Example 9.4 for creating a source from a distribution and the previous non-CADIS calculations for a fixed source analog MCNP model in Attila. The user can use the Cask in Room example to facilitate the use of the pre-made materials from PNNL's Compendium. Using Equation 9.2, the tally multiplier for the F4 tally on the person will be to obtain a dose rate in units of mrem per hour. That same value can be used in TecPlot as an equation to generate plots in dose rate or the plots can be left in units of dose per source particle. Example plots of the dose and error are presented below:




