In Section 3.6 we described how reactor fuel is depleted over time. In Example 3.4, we modeled our single pin unit cell in TRITRON and depleted it for just over 1500 days so we could see how the reactivity changed over time. In MCNP it is possible to deplete nuclear fuel in the same manner. Just like SCALE uses ORIGIN to estimate the burnup and depletion of fuel in between time steps, MCNP uses CINDER to calculate the isotopic concentrations based on the length of the burnup step, the initial composition of the fuel, and the power applied to the model.
Depletion can only be added to a KCODE model as MCNP will iterate between KCODE cycles and BURN steps in what is known as a predictor-corrector method. The BURN card is added in the DATA CARD section of the input file using the following format:
BURN KEYWORD=values(s)The values associated with the primary keywords are presented in Table 6.2.
Table 6.2. Keywords for BURN card and Descriptions. The complete list is in the User’s Manual. (Kulesza et al.; 2022)
| Keyword | Value |
|---|---|
TIME=t_1 t_2... | Incremental time duration t for each successive burn step. Time unit is days. (DEFAULT: one time step lasting on day) |
PFRAC=f_1 f_2 ... | Fraction f of total system power (pwr) applied to burn step t. Caution: if only a single PFRAC value (f) is provided, but multiple time steps (t) are specified, the first time step (t) wilL be assigned a power fraction of f; subsequent time steps will have a power fraction of 0. (DEFAULT: f = 1.0 for all t) |
POWER=pwr | Total recoverable fission system power (MW). (DEFAULT: POWER=1.0) |
MAT=m_1 m_2 ... | Material number m of material to be burned. Corresponds identically to material number specified on a material specification card Mm (DEFAULT: burn all materials) If m<o, then recoverable energy per fission and neutrons per fission are computed and contribute to the power normalization, but the material is not burned. (Warning: if you have duplicate ZAIDs on an M card of a material to be burned, wrong answers can result. MCNP6 will not give you a warning in this instance). |
BOPT=b_1 b_2 b_3 | b=Q value multiplier. (DEFAULT: b=1.0) The parameter b is used to control the ordering and content of the output and is the additive result of two integer values: b=I1+I2. The first value, I1, selects among three tiers (see Table 3-71 in the User’s Manual) of fission product content: The second value, I2, selects among four ordering options: The parameter for b is defined by: The parameter b allows the user to disallow the use of high-energy physics models if the cross-section energy is less than the benchmarked values. |
OMIT= m_1 n_1 j_{11} j_{12} … j_{1n1} m_2 n_2 j_{21} j_{22} ... j_{2n2} | For each specified material number, m, omit the following n isotopes from the transport calculation: j j … j. Each j must be provided in the form ZZZAAA, where ZZZ is the isotope’s atomic number and AAA is its atomic mass number. |
AFMIN= af_1 af_2 | af=Atom fraction below which an isotope will no longer be tracked in the transport calculation. If the atom fraction of an isotope falls below this limit, the atom fraction is set to 0. (DEFAULT: af = 1.0E-10) af=Transmutation chain convergence criteria used in CINDER90. (DEFAULT: af=1.0E-10) |
MATVOL=v_1 v_2… v_n | Used to provide the volume of all cells containing a burn material in a repeated structure or lattice geometry. Each v entry is the volume of all cells containing burn material mi. Each mi on MAT keyword needs a v. |
When we complete a BURN calculation, we may not need to use all of the KEYWORDs in Table 6.2. For example, we will only need to use a MATVOL keyword if we have a repeated lattice, which we will do in the next section. The fission product Tiers are described in the User’s Manual in Table 3-71. Unless we are tracking specific fission product isotopes, we can normally use Tier 1. In Example 6.4 we will add a BURN card to the model we used in Example 6.5. We will specify the model burns material 2, the fuel. For the power in the burnup, we will need to calculate the total MW that the single fuel pin contributes to the reactor. This is different than the specific power we used in SCALE. The power for a single fuel pin for a reactor that has on the order of 50,000 fuel rods operating at about 3000 MW is around 0.06 MW for each fuel pin.
Example 6.4
Use the model for the single unit fuel pin used in Example 6.4 to complete a burnup calculation for around 1500 days. Keep the moderator, cladding and gap temperature at 600 K and use 1200 K for the fuel. Plot the criticality as a function of time.
Solution: For our model, we added the following BURN card:
BURN TIME = 1 2 4 25 25 50 100 100 100 100 100 100 100 100 100100 100 100 100 100MAT = 2POWER = .06OMIT = 2 4 6014 7016 8018 9018
Hover a line
Each line is read as a cell, a surface, or a data card. Tap a line on a small screen.
- ●Cell cards
- ●Surface cards
- ●Data cards
The card can go right after KSRC line. We used small time steps to begin the model to build up the fission products. The total time is 1507 days. We are burning material 2 which is the UO at a power of 0.06 MW. Because we are using the default values for BOPT, when we run the model without the OMIT card, we get a fatal error indicating that tabular data is not available for 4 isotopes (6014 7016 8018 and 9018).
Because these isotopes are all formed in very small fractions in the fission process and they do not have significant neutron cross sections, we can add an OMIT card to remove them from the problem and prevent the fatal error from occurring. We could have chosen a different BOPT option, or we could have created cross sections for those isotopes using NJOY99 and added them to MCNP if we wanted to track them. If we choose a larger tier for fission products, we will get more isotopes that will not have tables.
Note that the total calculation will take some time. Each time step requires two complete KCODE calculations (1 predictor and 1 corrector). This means our model will do 40 total KCODE calculations and it may take an hour or more to complete.
When done, we can open the output file and find the burnup table and get the results. Note that the burnup table does not print the standard deviation. You must search through the output for each standard deviation for each step.
| Total | Total | |||||
|---|---|---|---|---|---|---|
| Time | k-Inf | Time | k-Inf | |||
| MCNP | MCNP | Variance | MCNP | MCNP | Variance | |
| 0.00E+00 | 1.44507 | 0.00176 | 6.07E+02 | 1.26293 | 0.00216 | |
| 1.00E+00 | 1.44435 | 0.00201 | 7.07E+02 | 1.23589 | 0.00181 | |
| 3.00E+00 | 1.44434 | 0.00198 | 8.07E+02 | 1.20415 | 0.00220 | |
| 7.00E+00 | 1.44444 | 0.00211 | 9.07E+02 | 1.17485 | 0.00231 | |
| 3.20E+01 | 1.43341 | 0.00209 | 1.01E+03 | 1.14024 | 0.00236 | |
| 5.70E+01 | 1.43380 | 0.00169 | 1.11E+03 | 1.10995 | 0.00207 | |
| 1.07E+02 | 1.41621 | 0.00214 | 1.21E+03 | 1.07386 | 0.00183 | |
| 2.07E+02 | 1.37887 | 0.00178 | 1.31E+03 | 1.04276 | 0.00171 | |
| 3.07E+02 | 1.34795 | 0.00201 | 1.41E+03 | 1.01094 | 0.00227 | |
| 4.07E+02 | 1.32105 | 0.00204 | 1.51E+03 | 0.98851 | 0.00184 | |
| 5.07E+02 | 1.28978 | 0.00180 |
We can then plot the depletion results for the MCNP model on the same chart as the results from the SCALE TRITON model we did in Example 3.4.

When we look at the results from both models, we see that the depletion curves are very similar in slope. The systematic difference in k that is initially present is consistent throughout. The MCNP model has a higher value. If we were trying to verify these results, we would need to determine the exact cause of the differences between the two approaches. Note that the standard deviation for the MCNP model is so small that the error bars are not visible in the plot.
References
Full bibliography- Kulesza, J. A., Adams, T. R., Armstrong, J. C., Bolding, S. R., Brown, F. B., Bull, J. S., Burke, T. P., Clark, A. R., Forster III, R. A., Giron, J. F., Grieve, T. S., Josey, C. J., Martz, R. L., McKinney, G. W., Pearson, E. J., Rising, M. E., Solomon Jr., C. J., Swaminarayan, S., Trahan, T. J., Wilson, S. C. and Zukaitis, A. J. (2022). MCNP Code Version 6.3.0 Theory & User Manual. https://www.osti.gov/biblio/1889957