On this page
One continuous section of the book; read it straight through.
Experimental results are subject to statistical uncertainty associated with the measured value. Because Monte Carlo techniques attempt to model actual random processes, they are also subject to the same uncertainty as experimental measurements. Unlike deterministic transport code results, Monte Carlo results should ALWAYS be reported with some measurement of the uncertainty included. As we saw in the figure in Example 4.1, the error associated with a Monte Carlo calculation is very sensitive to the number of trials performed.
Figure 4.5 is a depiction of the concept of the terms precision and accuracy which are used to describe our experimental and Monte Carlo results. A precise measurement has a small overall standard deviation while an accurate measurement is close to the expected or known value. A measurement can be either precise or accurate or, ideally, both.

As we saw earlier, we can measure the precision of our Monte Carlo calculations by calculating the standard deviation of the mean. In its general form, the standard deviation, , is given by Equation 4.9.
Where N is the total number of trials, is each measured value, and is the mean or average of all the measured values. From Equation 4.9, it is readily apparent the standard deviation will decrease as the number of trials increases which was observed in our Monte Carlo estimate of in Example 4.1. If we have sufficiently large populations, the difference between the average and measured values will be small and we can simplify Equation 4.9 to and approximation given by Equation 4.10.
If we make a computer program to perform a Monte Carlo calculation, we should include a routine to calculate the standard deviation. Fortunately, MCNP6.2 always performs a statistical analysis for the reported values. Unfortunately, users will often overlook the statistical analysis or report outcomes without the included variances. It is possible to have a model in MCNP that will give a reported value with a variance that is on the same order or even greater than the values such as k = 1.25 1.50. This value is, of course, meaningless. It is up to the user to analyze the output and adjust the model to reduce variances and ensure precision in the reported results. When a model is not precise, the dominate form of error is random. The simplest method to reduce random error in a Monte Carlo model is to increase the sample size. In certain cases, this method may be insufficient and other methods, known as variance reduction techniques, may have to be applied. We will discuss some variance reduction techniques available in MCNP later in the text.
Accuracy in Monte Carlo modeling is another potential issue. The overall model accuracy depends strongly on the foundation of the random walk process – the cross-sectional data. It is possible to have an excellent geometrical representation of a radiation transport model with details that exactly match the source, dimensions and materials and still achieve terrible results with the use of bad cross-sectional data. As we discovered when we plotted the cross sections for U at different temperatures and when we performed the estimate for the fuel temperature coefficient using SCALE, some cross sections are very temperature dependent. In addition to temperature, other factors may affect how the model simulates the environment. For example, if we mix hydrogen and oxygen in MCNP in the ratio and density of water, we will not get the same effect as if we specify the cross-section, is water. The reason for the difference is due to the rotational and vibrational states in the water molecule that affect how neutrons interact. The molecular cross section is not the same as the free-gas cross section. Again, it is up to the user to understand the output and to correctly account for any assumptions or simplifications to achieve results that are both precise and accurate.

When a measurement or model is inaccurate, the confidence intervals of the accepted and experimental results do not overlap. The dominate error associated with an inaccurate measurement is systematic. It is possible that the materials or geometry in an experiment were not those used in a model. Another example might be that the intrinsic detector efficiency was not the same as what was modeled. If systemic errors can be reasonably explained, the model can either be refined or the results may be useful.